4715 IceFree Hybrid XT Heated Vane
wind turbine control for onshore and offshore turbines in all weather conditions
digital inputs of turbine controllers or PLCs
0° to 360°, free rotation
high level square wave frequency (see manual for details)
amplitude equals supply voltage
other formats available using optional Hybrid Personality Module
0° = 100 Hz, 359° = 459 Hz
1° per Hz
10-bit resolution (<1° resolution)
linear to ±1°
no dead band
100 Hz to 459 Hz
0 Hz output indicates fault
1200 ohm minimum
threshold: <2.4 m/s (<5.4 mph)
ASTM D5366-96
Electronics
supply voltage: 8 to 24 V DC
supply current: 40 mA typical (not including heater)
Heater
supply voltage: 24 V (AC or DC)
supply current:
- self-regulating heater contained within an aluminum head
- 1 to 4A, thermal load dependent
- cold start inrush current: 9A peak
- inrush drops below 4A within 30 seconds
quick-release connector mount
braided shield with shield wire
600V rated insulation
outside diameter of cable = 8.89 mm (0.35 inches)
two heater wires (20 AWG)
three sensor wires: power, common, signal (22 AWG)
1.68 kg (3.71 lbs)
overall height: 247 mm (9.72 inches)
swept diameter of rotor: 150 mm (5.92 inches)
body diameter: 58 mm (2.28 inches)
twin-tail: anodized aluminum
body: zinc
shaft: stainless steel
bearing: double-shielded stainless steel ball bearings in a protective cartridge
UL61010-1
CE
-40° C to 60° C (-40° F to 140° F)
0 to 100% RH
IP55
IP5X Dust Intrusion per IEC 60529 and DIN40050-9
IPX5 Water Jet per IEC 60529 and DIN40050-9
MIL-STD-810F Method 509.4 (96 Hour Salt Fog Corrosion)
IEC 60068-2-52, Severity 1 (28 Day Salt Fog Corrosion) (pending verification)
IEC 60068-2-38 Z/AD (Cyclic Humidity & Temperature)
IEC 60068-2-78 (Constant Humidity)
Vibration Testing
IEC 60068-2-6
IEC 60068-2-64
MIL-STD-810G 514.6 Annex D per profile 514.6D III Category 14 (pending verification)
Packaging meets ISTA 1A Drop Test